July 17, 2007
EMLock® - SECURITY LEVELS
Because of the use of electromagnetic locks for many access control applications, careful concern should be given to choice of holding force and the need for battery back up. The SDC EMLock® Series is available in different holding force and design configurations to accommodate several different applications.
|
Model
|
Holding Foce
|
Configuration
|
Security Level
|
|
1581
|
650lbs
|
Surface Mount
|
Traffic Control
|
|
1571
|
1200lbs
|
Surface Mount
|
Medium Security
|
|
1511
|
1650lbs
|
Surface Mount
|
High Security
|
|
1561
|
2000lbs
|
HiShear Concealed or Surface Mount
|
High Security
|
|
1565
|
2700lbs
|
HiShear Concealed or Surface Mount
|
High Security
|
Battery Backup
Battery backup is recommended to compensate for the inherent failsafe operation in applications with higher security requirements, particularly on interior doors. When installed on perimeter doors, building and safety codes require magnetic locks to release during a building power loss and signal from the life safety system command center.
SURFACE MOUNT EMlock® APPLICATION
Traffic Control
Any magnetic lock with a holding force less than 1200 lbs. should only be used for traffic control, as would a light or medium duty electric strike. A holding force of 650 lbs (see figure 3) is typical for most magnetic locks fit for traffic control and they may be easily defeated. However, this is a benefit compared to the use of light duty electric strikes. As the electric strike may break when forced, a low holding force magnetic lock will release without damage and the door will simply relock when closed.
Medium Security
Magnetic locks mounted on an aluminum glass door are capable of providing medium security because the glass door is more likely to shatter before a lock with 1200 lbs. (see figure 3) of holding force will release. For this reason, a lock with 1200 lbs. of holding force is sufficient for aluminum and glass openings and many commercial interior installations where aggressive attacks are not expected, such as openings made of metal frames and wood or hollow metal doors.
High Security
It is important to note that the term ‘high security’ is used only in the context of a failsafe magnetic door lock application, which cannot compare to the integrity provided by electromechanical locking devices, such as failsafe and failsecure electrified locksets, electric deadbolts or heavy-duty electric strikes.
For most commercial and industrial high security applications with Herculite glass doors or hollow metal frames with wood or hollow metal doors, an electromagnetic door lock with at least 1500 lbs.(see figure 3) of holding force is recommended. When attacked with extreme force, these doors may not release, but may sustain damage.
While many installers may feel that 1200 lbs. of holding force is ample for any installation, it must be noted, that when these locks are overcome with force, the door will simply close and relock, with no one the wiser about the security breach.
For example, in psychiatric facilities, aggressive patients have been known to force open doors equipped with 1200 lbs. holding force magnetic locks. It is not uncommon for some facilities to upgrade to a 1650lb holding force EMLock® after experiencing more than one breach.
HiShear® APPLICATION
Concealed HiShear®
HiShear magnetic shear locks (see figure 4) are generally used for openings that require an architecturally superior appearance. When installed on openings with hollow metal frames and wood or hollow metal doors, a magnetic shear lock with a holding force of 2000 lbs. or more is capable of withstanding a force that will deform or destroy the door beyond repair before it is released. However, when installed on glass doors, the contact point between the armature and magnetic lock will be exposed to tampering on both sides of the opening.
Shear locks have more critical alignment issues than typical surface mount magnetic locks. A valuable tip for trouble free shear lock installation is the use of a Positive Centering or Heavy Duty door closer for double acting aluminum glass and Herculite doors. Standard duty double acting door closers may tend to swing back and forth before resting and eventually become misaligned, requiring frequent adjustment servicing. To eliminate this problem, the installation of a heavy duty closer causes the doors to quickly rest in the center position and greatly reduce service calls. This is something that can be installed easily by most locksmiths or door professionals.
Semi-Concealed HiShear Application
Simi Concealed HiShear magnetic locks (see figure 5) accommodate offset hung glass doors, plus they provide a high security alternative to standard surface mount magnetic locks when used on hollow metal frames with wood or hollow metal doors. At the same time, it still provides superior appearance while the magnet is concealed in the frame and only the small armature housing is surface mounted to the top of the door.
Surface Mount HiShear Application
Almost half the size of a typical surface mount EMLock®, surface mount HiShear magnetic locks (see figure 6) provide a higher level of security for glass doors or metal door and frames.